49 C.F.R. 193.2013   Incorporation by reference.


Title 49 - Transportation


Title 49: Transportation
PART 193—LIQUEFIED NATURAL GAS FACILITIES: FEDERAL SAFETY STANDARDS
Subpart A—General

Browse Previous |  Browse Next

193.2013   Incorporation by reference.

(a) Any document or portion thereof incorporated by reference in this part is included in this part as though it were printed in full. When only a portion of a document is referenced, then this part incorporates only that referenced portion of the document and the remainder is not incorporated. Applicable editions are listed in paragraph (c) of this section in parentheses following the title of the referenced material. Earlier editions listed in previous editions of this section may be used for components manufactured, designed, or installed in accordance with those earlier editions at the time they were listed. The user must refer to the appropriate previous edition of 49 CFR for a listing of the earlier editions.

(b) All incorporated materials are available for inspection in the Pipeline and Hazardous Materials Safety Administration, 400 Seventh Street, SW., Washington, DC, or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202–741–6030 or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/IBR_locations.html.

Documents incorporated by reference are available from the publishers as follows:

A. American Gas Association (AGA), 400 North Capitol Street, NW., Washington, DC 20001.

B. American Society of Civil Engineers (ASCE), Parallel Centre, 1801 Alexander Bell Drive, Reston, VA 20191–4400.

C. ASME International (ASME), Three Park Avenue, New York, NY 10016–5990.

D. Gas Technology Institute (GTI), 1700 S. Mount Prospect Road, Des Plaines, IL 60018.

E. National Fire Protection Association (NFPA), 1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02269–9101.

(c) Documents incorporated by reference.

 ------------------------------------------------------------------------    Source and name of referenced material          49 CFR reference------------------------------------------------------------------------A. American Gas Association (AGA):  (1) ``Purging Principles and Practices,''    §§ 193.2513;   (3rd edition, 2001)..                        193.2517; 193.2615.B. American Society of Civil Engineers (ASCE):  (1) SEI/ASCE 7-02 ``Minimum Design Loads     § 193.2067.   for Buildings and Other Structures,''   (2002 edition)..C. ASME International (ASME):  (1) ASME Boiler and Pressure Vessel Code,    § 193.2321.   Section VIII, Division 1, ``Rules for   Construction of Pressure Vessels,'' (2004   edition, including addenda through July 1,   2005).  (2) ASME Boiler and Pressure Vessel Code,    § 193.2321.   Section VIII, Division 2, ``Rules for   Construction of Pressure   Vessels_Alternative Rules,'' (2004   edition, including addenda through July 1,   2005).D. Gas Technology Institute (GTI):  (1) GRI-89/0176 ``LNGFIRE: A Thermal         § 193.2057.   Radiation Model for LNG Fires,'' (June 29,   1990).  (2) GTI-04/0049 (April 2004) ``LNG Vapor     § 193.2059.   Dispersion Prediction with the DEGADIS   2.1: Dense Gas Dispersion Model for LNG   Vapor Dispersion''.  (3) GRI-96/0396.5 ``Evaluation of            § 193.2059.   Mitigation Methods for Accidental LNG   Releases, Volume 5: Using FEM3A for LNG   Accident Consequence Analyses,'' (April   1997).E. National Fire Protection Association (NFPA):  (1) NFPA 59A (2001) ``Standard for the       §§ 193.2019;   Production, Storage, and Handling of         193.2051; 193.2057;   Liquefied Natural Gas (LNG).''.              193.2059; 193.2101;                                                193.2301; 193.2303;                                                193.2401; 193.2521;                                                193.2639; 193.2801.------------------------------------------------------------------------

[Amdt. 193–19, 71 FR 33408, June 9, 2006]

Browse Previous |  Browse Next

chanrobles.com