49 C.F.R. § 195.559 What coating material may I use for external corrosion control?
Title 49 - Transportation
Coating material for external corrosion control under §195.557 must— (a) Be designed to mitigate corrosion of the buried or submerged pipeline; (b) Have sufficient adhesion to the metal surface to prevent under film migration of moisture; (c) Be sufficiently ductile to resist cracking; (d) Have enough strength to resist damage due to handling and soil stress; (e) Support any supplemental cathodic protection; and (f) If the coating is an insulating type, have low moisture absorption and provide high electrical resistance.
Title 49: Transportation
PART 195—TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE
Subpart H—Corrosion Control
§ 195.559 What coating material may I use for external corrosion control?