ANNEX B-TABLES
Table 3.01-A
DIMENSIONS OF WOODEN POSTS OR SUPORTALES 1


 Type of  Maximum Maximum Maximum Required Maximum
 Building Height of  Height Spacing of  Finished Size of
  1st Floor Total Posts Suportales

1-Storey Shed   4.00 m.  350 m.  10 cms. x 10 cms. (4" x 4")
1-Storey Shed   3.00 m.  4.00 m.  10 cms. x 10 cms. (4" x 4")
1-Storey Shed   5.00 m.  4.00 m.  12.5 cms x 12.5 cms. (5" x 5")
1-Storey Shed  1.00 to  5.50 m.  3.50 m.  12.5 cms. x 12.5 cms. or Chalet  1.50 m. (5" x 5")
2- Storey House  3.00 m.  6.00 m.  300 m.  12.5 cms. x 12.5 cms. (5" x 5")
2-Storey House  3.50 m.  7.00 m.  4.00 m.  12 cms. x 15 cms. (6" x "6)
2-Storey House  4.50 m.  8.00 m.  4.50 m.  17.5 cms. x 17.5. cms. ("7 x "7)
2-Storey House  5.00 m.  9.00 m.  4.50 m.  20 cms. x 20 cms. (8" x 8")


1 Logs or tree trunk suportales may be used as posts in indigenous traditional type of construction, provided that these are of such sizes and spacing as to sustain vertical loading equivalent at least to the loading capacities of the posts and spacing in this Table.
 
Table 6.01-A
PROJECTION OF BALCONIES AND APPENDAGES

Width of Street  1 Balcony Maximum Projection  2
2.00 m. to less 3.00 m.  No balcony  0.30 m.
3.00 m.  No balcony  0.45 m.

Over 3.00 m. but less than 8.00 m.  With balcony  0.80 m.
8.00 m. to less than 10.00 m.  With balcony  1.00 m.
10.00 m. to less than 11.00 m.  With balcony  1.00 m.
11.00 m. to less than 12.00 m.  With balcony  1.10 m.
12.00 m. to less than 13.00 m.  With balcony  1.30 m.
13.00 m. to less than 14.00 m.  With balcony  1.40 m.
14.00 m. or over  With balcony  1.50 m.


1 The width of streets is the total width of the right-of-way measured from the property line to property line.
 
2 The maximum projection shall be measured from the property line to the outermost part of the projection. No projection shall be allowed on national roads and public highways.
 
Table 6.02-A
TYPE OF PROTECTION REQUIRED FOR
PEDESTRIANS 1

 Height of   Protection
 Construction  Distance from Construction  Required
 2.40 Meters  Less than 1.80 Meters (6 feet)  Railing
 (8 feet) or less
  1.80 meters (6 feet) or more  None
  Less than 1.80 Meters (6 feet)  Fence and
 More than   Canopy
  1.80 Meters (6 feet) or more, but not more
   than one-fourth the height of construction Fence and
   Canopy
 2.40 Meters
   1.80 Meters (6 feet) or more, but between Fence
  one-fourth to one-half the height of
  construction
 (8 feet)
  180 Meters (6 feet) or more, but exceeding None
  one-half the height of construction
1 All protective devices shall include appropriate lights and warning signs.

National Building Code of the Philippines