A
collection of Philippine laws, statutes and codesnot
included or cited in the
main indicesof
theChan Robles Virtual Law LibraryThis page features the full text ofRepublic
Act No. 6541Annex
"B".chanrobles virtual law libraryThe National Building Code of
the
Philippines
REPUBLIC ACT NO.
6541
AN ACT TO ORDAIN
AND
INSTITUTEA NATIONAL
BUILDING
CODE OF THE PHILIPPINES
ANNEX B-TABLESTable 3.01-ADIMENSIONS OF
WOODEN
POSTS OR SUPORTALES 1
Type
of Maximum Maximum Maximum Required Maximum Building Height
of Height
Spacing of Finished Size of 1st Floor Total Posts
Suportales
1-Storey Shed 4.00
m. 350
m. 10 cms. x 10 cms.
(4" x 4")
1-Storey Shed 3.00
m.
4.00 m. 10 cms. x 10 cms.
(4" x 4")
1-Storey Shed 5.00
m.
4.00 m. 12.5 cms x 12.5 cms.
(5" x 5")
1-Storey Shed 1.00 to
5.50
m. 3.50 m. 12.5 cms. x 12.5 cms.
or
Chalet
1.50
m. (5" x 5")
2- Storey House 3.00 m.
6.00
m. 300 m. 12.5 cms. x 12.5 cms.
(5" x 5")
2-Storey House 3.50 m.
7.00
m. 4.00 m. 12 cms. x 15 cms.
(6" x "6)
2-Storey House 4.50 m.
8.00
m. 4.50 m. 17.5 cms. x 17.5. cms.
("7 x "7)
2-Storey House 5.00 m.
9.00
m. 4.50 m. 20 cms. x 20 cms.
(8" x 8")
1 Logs or tree trunk suportales may
be
used as posts in indigenous traditional type of construction, provided
that these are of such sizes and spacing as to sustain vertical loading
equivalent at least to the loading capacities of the posts and spacing
in this Table.
Table 6.01-APROJECTION OF BALCONIES AND
APPENDAGES
Width of Street 1 Balcony
Maximum
Projection 2
2.00 m. to less 3.00 m. No
balcony
0.30 m.
3.00 m. No balcony 0.45 m.
Over 3.00 m. but less than 8.00
m.
With balcony 0.80 m.
8.00 m. to less than 10.00 m.
With
balcony 1.00 m.
10.00 m. to less than 11.00 m.
With
balcony 1.00 m.
11.00 m. to less than 12.00 m.
With
balcony 1.10 m.
12.00 m. to less than 13.00 m.
With
balcony 1.30 m.
13.00 m. to less than 14.00 m.
With
balcony 1.40 m.
14.00 m. or over With
balcony
1.50 m.
1 The width of streets is the total
width
of the right-of-way measured from the property line to property line.
2 The maximum projection shall be
measured
from the property line to the outermost part of the projection. No
projection
shall be allowed on national roads and public highways.
Table 6.02-ATYPE OF PROTECTION REQUIRED
FORPEDESTRIANS 1
Height of
Protection
Construction Distance
from
Construction Required
2.40 Meters Less than
1.80
Meters (6 feet) Railing
(8 feet) or less
1.80 meters (6 feet) or
more
None
Less than 1.80 Meters (6
feet)
Fence and
More than Canopy
1.80 Meters (6 feet) or more,
but
not more
than one-fourth the
height
of construction Fence and
Canopy
2.40 Meters
1.80 Meters (6 feet) or
more,
but between Fence
one-fourth to one-half the
height
of
construction
(8 feet)
180 Meters (6 feet) or more,
but
exceeding None
one-half the height of
construction
1 All protective devices shall
include
appropriate lights and warning signs.
Back
to Top - Back
to Main Index - Back
to Home
chanroblesvirtualawlibrary
Copyright
1998-2006
by
ChanRobles
Publishing Company
All Rights Reserved
Since 19.07.98
|